Product Features
:: | Measures pH and Ion with up to 0.001 Resolution. |
:: | Cal-Due Alarm Prevents Out-dated Calibrations, while Set-Point Alarms warns when readings are outside set-point limits. |
:: | Higher accuracy under varying temperature with Automatic/ Manual Temperature Compensation. |
:: | Mega-memory space that stores/ recalls up to 500 Data Sets with temperature readings, with time and date-stamping formatted to meet GLP standards. |
:: | Wireless and cable-free data transfer with infrared IrDA technology. Comes with PC-based Complimentary Data Acquisition Software for hassle-free data import and report-generation into any popular spreadsheet programs of your choice. |
:: | Recall Electrode Slope, Electrode Offset Value and Previous Calibration Values for easy reference |
:: | Large, Easy-to-Read Custom Display with simultaneous readings provides optimum viewing with user-friendly icons |
:: | Hold Function momentarily freezes reading for easy viewing and recording |
:: | Self-Diagnostic with message codes for easy troubleshooting |
:: | Volatile Memory holds settings and stored data even when you run out of batteries. |
:: | Rugged and waterproof to IP67 standard with protective rubber boot and handy velcro strap for better grip. |
:: | Power with batteries or optional AC adapter for use in the field or at bench-top with built-in stand. |
:: |
Energy-saving with Auto-power off feature. |
Specifications
Product Specification |
Description |
pH Range | -2.000 to 19.999 pH |
Resolution & Accuracy (±1 LSD) | 0.1/ 0.01/ 0.001& ±0.002 pH |
mV Range | ±2000 mV |
Resolution & Accuracy (±1 LSD) | 0.1 mV & ±0.2 mV |
Ion Range | 0.001 to 19900 |
Units | ppm/ molar/ mgL |
Resolution & Accuracy | 2/ 3 digits & 0.5% FS (Monovalent) / 1% (Divalent) |
Temperature Range | -10.0 to 110.0 °C (14.0 to 230 °F) |
Resolution & Accuracy | 0.1 °C/ 1.0°F |
Temperature Compensation | Automatic / Manual (0 to 100 °C) |
No. of Calibration Points | Up to 6 points |
Cal Due Alarm | Yes (Days - Max 30) |
pH Buffer Options | USA, NIST, DIN, PWB |
Custom Buffer Calibration | Yes (2 to 5) |
Slope/ Offset Display | Yes (Display + Icon) |
Inputs | DC phono sockets, 8 pin connector, BNC |
LCD Display | Back-lit Dot Matrix |
Memory | 500 data sets |
Output | Yes (IrDA/ RS232C) |
Special Functions | Stability Indicator; Self-diagnostic; Non-Volatile Memory; Hold & Auto-Power Off after 20 minutes |
GLP | Yes |
Ingress Protection | IP67 |
Power | 4 'AAA' x 1.4V batteries or 9VDC power adapter |