Target Gas
Electrochemical Sensors : Ammonia (NH3), Carbon monoxide (CO), Chlorine (Cl2), Chlorine dioxide (ClO2), Ethylene (C2H4), Ethylene oxide (C2H4O), Fluorine (F2), Formaldehyde (CH2O), Hydrogen (H2), Hydrogen chloride (HCl), Hydrogen cyanide (HCN), Hydrogen fluoride (HF), Hydrogen sulphide (H2S), Nitric oxide (NO), Nitrogen dioxide (NO2), Oxygen (O2), Ozone (O3), Phosphine (PH3), Silane (SiH4), Sulphur dioxide (SO2)
Solid State Sensors : Refrigerants R22, R134A, R402A, R404A, R407C, R410A, R422D, R438A, R438A, R507A, TVOCs
Infrared Sensor : Carbon dioxide (CO2)
Target Gas
Catalytic Sensors : Hydrogen (H2), Methane (CH4), Propane (C3H8)
PID Sensors : TVOC
Mechanical
Enclosure : Black ABS / Polycarbonate, corrosion resistant
Copper coated interior to reduce RF interference
IP54 rated with standard splash guard installed (Option -S)
Weight : 400 g / 14 oz
Size : 127 x 127 x 76 mm / 5.0 x 5.0 x 3.0 inches
User Interface
Display (standard) : 2-line by 16 character graphic LCD
Operating Temp: 0°C to 40°C / 32°F to 104°F
Display (Option -LT)* : 2-line by 16 character OLED display for cold environment applications down to -40°C / -40°F
Push Buttons : Initiate calibration and menu options with internal UP, DOWN and ENTER push buttons
USB Port : Internal port for USB memory stick for field firmware / configuration upgrades
Input/Output
Communication : User configurable in the field, BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485
RH & Temperature (Option -RHT)** : User selectable units DegC or DegF
Relay (Option -RLY)*** : One SPDT dry contact relay, rated 30 volts, 2 amps max
Electrical
Power Requirement : 16-30 VDC, 3 W, Class 2
12-27 VAC, 50-60 Hz, 3 VA, Class 2
Wiring : VDC or VAC (ground referenced) 4-conductor shielded 16 AWG stranded within conduit, network wiring (daisy-chain)
Fuse(s) : Automatic resetting thermal
Environmental
Operating Temperature : -40°C to 40°C (-40°F to 104°F), temperatures below 0°C / 32°F require Option-LT
Operating Humidity : 15 - 90% RH non-condensing
Certifications
Conforms to : CSA-C22.2 No. 205-12, UL508 (Edition 18):2018
EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Listed by BTL
RoHS compliant circuit boards